Model | V11P | V11V | V11C |
Pressure range | 0 ~ 1,000 kPa | -101.3 ~ 10 kPa | -101 ~ 101 kPa |
Withstand pressure | 1,500 kPa | 500 kPa | 500 kPa |
Fluid | Filtered air, Non-corrosive, Non-flammable gas |
Set pressure resolution | kPa | – | 0.1 | 0.1 |
MPa | 0.001 | – | – |
Kgf/cm² | 0.01 | 0.001 | 0.001 |
bar | 0.01 | 0.001 | 0.001 |
psi | 0.1 | 0.01 | 0.01 |
inHg | – | 0.1 | 0.1 |
mmHg | – | 1 | 1 |
Power supply voltage | 12 to 24V DC±10%, Ripple (P-P) 10% or less |
Current consumption | ≤40mA (With no load) |
Switch output | Output type | 2-NPN or 2-PNP open collector |
Max. load current | 125 mA |
Max. supply voltage | 30V DC @ NPN output, 24V DC @ PNP output |
Residual voltage | ≤1.5V |
Response time | ≤2.5 ms (Chattering-proof function: 25, 100, 250, 500, 1000, 1500 ms selections) |
Output short prot. | Yes |
Analog output | Voltage output | 1 ~ 5 V (±2.5%) |
Voltage impedance | About 1 Ω |
Linearity | ±1% F.S. |
Display | LED Display | 4 digit, 7 segment (red) |
Switch ON indicator | Out-1 red/ Out-2 green |
Updates time | About 0.2 s |
Indicator accuracy | ±2% F.S. ±1 digit (ambient temperature: 25±3℃) |
Repeatability (Switch output) | ±0.2% F.S. ±1 digit |
Environment | Enclosure | IP40 |
Operation temp. | 0 ~ 50℃ |
Storage ambient temp. | -10 ~ 60℃ (No condensation or freezing) |
Ambient voltage | 35 ~ 85% RH (No condensation) |
Withstand voltage | 1000V AC in -1min (between case and lead wire) |
Insulation resistance | 500 MΩ (at 500V DC, between case and lead wire) |
Vibration | Total amplitude 1.5mm or 10G, 10~55 Hz scan for 1-min, 2-hour each direction of X, Y, and Z |
Shock | 980 m/s² (10G), 3-time each in direction of X, Y, and Z |
Temperature characteristic | ±2% F.S. of detected pressure (25℃) at temp. range of 0 ~ 50℃ |
Port size | M5 |
Lead wire | 26 AWG, UL AWM 20276, 1000 mm |
Weight | 34.5 g (with 1-meter lead wire) |